Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique

Authors

  • Karina Bergamo Cardoso Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Prótese e Periodontia, Bauru http://orcid.org/0000-0002-7861-7348
  • Edmara Tatiely Pedroso Bergamo Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Prótese e Periodontia, Bauru
  • Vitor De Moraes Cruz Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos, Bauru
  • Ilana Santos Ramalho Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Prótese e Periodontia, Bauru
  • Lucas Fracassi De Oliveira Lino Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Prótese e Periodontia, Bauru
  • Estevam Augusto Bonfante Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Prótese e Periodontia, Bauru http://orcid.org/0000-0001-6867-8350

DOI:

https://doi.org/10.1590/1678-7757-2020-0343%20

Keywords:

Dental implants, Dental abutments, X-ray microtomography

Abstract

An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology: Volumetric and linear (central and marginal) gaps of four Ti-base abutments (n=10/group): (i) Odontofix LTDA (OD), (ii) Singular Implants (SING), (iii) EFF Dental Components (EFF), and (iv) Control Group (S.I.N implants) compatible with an implant system (Strong SW, S.I.N Implants) were measured using μCT reconstructed polyvinyl siloxane replicas. Results: The results showed significantly lower volume gap for Control S.I.N (0.67±0.29 mm3) and SING (0.69±0.28 mm3) Ti-base abutments relative to OD (1.42±0.28 mm3) and EFF groups (1.04±0.28 mm3) (p<0.033), without significant difference between them (p=0.936). While gap values were homogenous in the central region, EFF presented a significantly higher marginal gap. Accordingly, the Control S.I.N and Singular Ti-base abutments showed improved volumetric and marginal fit relative to Odontofix and EFF. Conclusion: The method of manufacturing abutments influenced the misfit at the implant-abutment interface.

Downloads

Download data is not yet available.

Downloads

Published

2021-09-22 — Updated on 2021-09-22

Versions

Issue

Section

Original Articles

How to Cite

Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique. (2021). Journal of Applied Oral Science, 28, e20200343. https://doi.org/10.1590/1678-7757-2020-0343