Influence of manufacturing methods and use of CoCr-based abutments on vertical and horizontal marginal fit and torque loss in implant-supported prostheses

Authors

DOI:

https://doi.org/10.1590/

Keywords:

Dental Implant, CAD/CAM, Zirconia

Abstract

Objectives  This in vitro study evaluated implant-supported single crowns with external connections fabricated using different techniques (cast and CAD/CAM) and materials (metal-ceramic and translucent zirconia) regarding vertical and horizontal marginal fit and torque loss before and after mechanical cycling. Methodology  A total of 50 specimens prepared using cast (lost wax) and CAD/CAM were divided into five groups—MC (metal–ceramic crowns), ZrB (Co-Cr base, coping milled in zirconia and feldspathic ceramic veneering), Zr (coping milled in zirconia and feldspathic ceramic veneering), MZrB (Co-Cr base and monolithic translucent zirconia crown), and MZr (monolithic translucent zirconia crown)—and subjected to 5×10⁶ mechanical cycles at a 30° angle at 37°C, and an applied load of 150N at 2Hz. All crowns were screwed with a 30Ncm torque. Vertical and horizontal marginal misfit (measured using a 3D optical microscope) and torque loss were assessed before and after mechanical cycling. Statistical analyses used a significance value of 0.05. Results  Before cycling, MC (93.93±22.84µm) and MZrB (66.12±11.87µm) (p<0.05) crowns showed significantly higher vertical marginal misfit values than Zr (49.92±3µm) and MZr (49.76±3,9µm). ZrB (59.96±4.66µm) crowns exhibited no statistically significant difference when compared with the other groups. MC crowns presented the highest horizontal marginal misfit values before and after cycling in group comparisons (p<0.05). MZrB had the highest torque loss (10N), with a statically significant difference when compared with MZr and Zr (p<0.05). Comparison between all groups showed no significant difference regarding the effect of mechanical cycling (p>0.05). Conclusion  CAD/CAM manufacturing resulted in lower vertical and horizontal marginal misfit values, especially for monolithic translucent zirconia crowns (MZr) before and after mechanical cycling. All groups presented torque loss before and after mechanical cycling.

Downloads

Download data is not yet available.

References

Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res 2012;23:2-21. doi: 10.1111/j.1600-0501.2012.02547.x. »https://doi.org/10.1111/j.1600-0501.2012.02547.x.

Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10- year period. Scand J Plast Reconstr Surg Suppl 1977;16:1-132.

Lemos CA, Verri FR, Gomes JM, Souza Batista VE, Cruz RS, Oliveira HF, et al. Ceramic versus metal-ceramic implant-supported prostheses: a systematic review and meta-analysis. J Prosthet Dent. 2019;121:879-86.e4. doi: 10.1016/j.prosdent.2018.09.016.

»https://doi.org/10.1016/j.prosdent.2018.09.016.

Mello CC, Lemos CA, Luna Gomes JM, Verri FR, Pellizzer EP. CAD/CAM vs conventional technique for fabrication of implant-supported frameworks: a systematic review and meta-analysis of in vitro studies. Int J Prosthodont. 2019;32:182-92. doi: 10.11607/ijp.5616. »https://doi.org/10.11607/ijp.5616.

Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of margin ?t. J Prosthet Dent. 1989;62:405-8. doi: 10.1016/0022-3913(89)90170-4. »https://doi.org/10.1016/0022-3913(89)90170-4.

Nascimento Cd, Pita MS, Santos ES, Monesi N, Pedrazzi V, Albuquerque RF Junior, et al. Microbiome of titanium and zirconia dental implants abutments. Dent Mater. 2016;32:93-101. doi: 10.1016/j.dental.2015.10.014. »https://doi.org/10.1016/j.dental.2015.10.014.

Azevedo-Vaz SL, Araujo-Siqueira C, Carneiro VC, Oliveira ML, Azeredo RA. Misfit detection in implant-supported prostheses of different compositions by periapical radiography and cone beam computed tomography: an in vitro study. J Prosthet Dent. 2021;126(2):205-13. doi: 10.1016/j.prosdent.2020.04.020. »https://doi.org/10.1016/j.prosdent.2020.04.020.

Misch, CE. Prótese sobre implantes. 1. ed. São Paulo: Ed. Santos, 2006.

Huang Y, Wang J. Mechanism of and factors associated with the loosening of the implant abutment screw: a review. J Esthet Restor Dent. 2019;31:338-45. doi: 10.1111/jerd.12494. »https://doi.org/10.1111/jerd.12494.

Sammour SR, Maamoun El-Sheikh M, Aly El-Gendy A. Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: in-vitro study. Dent Mater. 2019;35:e265-e271. doi: 10.1016/j.dental.2019.07.026. »https://doi.org/10.1016/j.dental.2019.07.026.

Santiago JF, Souza Batista VE, Verri FR, Honorio HM, Mello CC, Almeida DA, et al. Platform-switching implants and bone preservation: a systematic review and meta-analysis. Int J Oral Maxillofac Surg. 2016;45:332-45. doi: 10.1016/j.ijom.2015.11.009. »https://doi.org/10.1016/j.ijom.2015.11.009.

Queiroz DA, Hagee N, Lee DJ, Zheng F. The behavior of a zirconia or metal abutment on the implant-abutment interface during cyclic loading. J Prosthet Dent. 2020;124(2):211-6. doi: 10.1016/j.prosdent.2019.09.023. »https://doi.org/10.1016/j.prosdent.2019.09.023.

Abduo J, Lyons K, Bennani V, Waddell N, Swain M. Fit of screw-retained fixed implant frameworks fabricated by different methods: a systematic review. Int J Prosthodont. 2011;24:207-20.

Schiroli G. Single-tooth implant restorations in the esthetic zone with Pure Form ceramic crowns: 3 case reports. J Oral Implantol. 2004;30:358-63. doi: 10.1563/0.724.1. »https://doi.org/10.1563/0.724.1.

Oliveira MN, Schunemann WV, Mathew MT, Henriques B, Magini RS, Teughels W, et al. Can degradation products released from dental implants affect peri-implant tissues? J Periodontal Res. 2018;53:1-11. doi: 10.1111/jre.12479. »https://doi.org/10.1111/jre.12479.

Sailer I, Strasding M, Valente NA, Zwahlen M, Liu S, Pjetursson BE. A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic multiple-unit fixed dental prostheses. Clin Oral Implants Res. 2018;29:184-98. doi: 10.1111/clr.13277. »https://doi.org/10.1111/clr.13277.

Pjetursson BE, Valente NA, Strasding M, Zwahlen M, Liu S, Sailer I. A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic single crowns. Clin Oral Implants Res. 2018;29:199-214. doi: 10.1111/clr.13306. »https://doi.org/10.1111/clr.13306.

Garine WN, Funkenbusch PD, Ercoli C, Wodenscheck J, Murphy WC. Measurement of the rotational misfit and implant-abutment gap of all-ceramic abutments. Int J Oral Maxillofac Implants. 2007;22:928-38.

Pereira PH, Amaral M, Baroudi K, Vitti RP, Nassani MZ, Silva-Concílio LR. Effect of implant platform connection and abutment material on removal torque and implant hexagon plastic deformation. Eur J Dent. 2019;13:349-53. doi: 10.1055/s-0039-1700662. »https://doi.org/10.1055/s-0039-1700662.

International Organisation for Standardization. ISO 14801:2016 - Dentistry- Implants- Dynamic fatigue test for endosseous dental implants. Geneva: ISO; 2016.

Moris IC, Faria AC, Ribeiro RF, Fok AS, Rodrigues RC. Custom morse taper zirconia abutments: influence on marginal fit and torque loss before and after thermomechanical cycling. J Mech Behav Biomed Mater. 2018;78:241-5. doi: 10.1016/j.jmbbm.2017.11.027. »https://doi.org/10.1016/j.jmbbm.2017.11.027.

Bitencourt SB, Santos DM, Silva EV, Barão VA, Rangel EC, Cruz NC, et al. Characterisation of a new plasma-enhanced film to improve shear bond strength between zirconia and veneering ceramic. Mater Sci Eng C Mater Biol Appl. 2018;92:196-205. doi: 10.1016/j.msec.2018.06.052. » https://doi.org/10.1016/j.msec.2018.06.052.

Thompson VP, Rekow DE. Dental ceramics and the molar crown testing ground. J Appl Oral Sci. 2004;12:26-36. doi: 10.1590/s1678-77572004000500004. »https://doi.org/10.1590/s1678-77572004000500004.

Kim JH, Lee SJ, Park JS, Ryu JJ. Fracture load of monolithic CAD/CAM lithium disilicate ceramic crowns and veneered zirconia crowns as a posterior implant restoration. Implant Dent. 2013;22:66-70. doi: 10.1097/ID.0b013e318278a576. »https://doi.org/10.1097/ID.0b013e318278a576.

Sciasci P, Abi-Rached FO, Adabo GL, Baldissara P, Fonseca RG. Effect of surface treatments on the shear bond strength of luting cements to Y-TZP ceramic. J Prosthet Dent. 2015;113:212-9. doi: 10.1016/j.prosdent.2014.09.012. »https://doi.org/10.1016/j.prosdent.2014.09.012.

Mehl C, Zhang Q, Lehmann F, Kern M. Retention of zirconia on titanium in two-piece abutments with self-adhesive resin cements. J Prosthet Dent. 2018;120:214-9. doi: 10.1016/j.prosdent.2017.11.020. »https://doi.org/10.1016/j.prosdent.2017.11.020.

Basílio MA, Abi-Rached FO, Butignon LE, Arioli Filho JN. Influence of liquid lubrication on the screw-joint stability of Y-TZP implant abutment systems. J Prosthodont. 2017;26:656-8. doi: 10.1111/jopr.12456. »https://doi.org/10.1111/jopr.12456.

Pellizzer EP, Mello CC, Gomes JM, Santiago Júnior JF, Lemos CA, Verri FR. Vertical and horizontal misfit analysis of 3-unit FDP fabricated with different techniques and CAD/CAM Systems. Braz Dent J. 2018;29:342-6. doi: 10.1590/0103-6440201801916. »https://doi.org/10.1590/0103-6440201801916.

Wiskott HW, Nicholls JI, Belser UC. Fatigue resistance of soldered joints: a methodological study. Dent Mater. 1994;10:215-20. doi: 10.1016/0109-5641(94)90035-3. »https://doi.org/10.1016/0109-5641(94)90035-3.

Amaral M, Villefort RF, Melo RM, Pereira GK, Zhang Y, Valandro LF, et al. Fatigue limit of monolithic Y-TZP three-unit-fixed dental prostheses: effect of grinding at the gingival zone of the connector. J Mech Behav Biomed Mater. 2017;72:159-62. doi: 10.1016/j.jmbbm.2017.03.002. »https://doi.org/10.1016/j.jmbbm.2017.03.002.

Mericske-Stern R, Zarb GA. In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants. Clin Oral Implants Res. 1996;7:153-61. doi: 10.1034/j.1600-0501.1996.070209.x. »https://doi.org/10.1034/j.1600-0501.1996.070209.x.

Farina AP, Spazzin AO, Pantoja JM, Consani RL, Mesquita MF. An in vitro comparison of joint stability of implant-supported fixed prosthetic suprastructures retained with different prosthetic screws and levels of fit under masticatory simulation conditions. Int J Oral Maxillofac Implants. 2012;27:833-8.

Bhering CL, Takahashi JM, Luthi LF, Henriques GE, Consani RL, Mesquita MF. Influence of the casting technique and dynamic loading on screw detorque and misfit of single unit implant-supported prostheses. Acta Odontol Scand. 2013;71:404-9. doi: 10.3109/00016357.2012.690528. »https://doi.org/10.3109/00016357.2012.690528.

Moilanen P, Hjerppe J, Lassila LV, Närhi TO. Fracture strength and precision of fit of implant-retained monolithic zirconia crowns. J Oral Implantol. 2018;44:330-4. doi: 10.1563/aaid-joi-D-17-00249. »https://doi.org/10.1563/aaid-joi-D-17-00249.

Pardal-Peláez B, Montero J. Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review. J Clin Exp Dent. 2017;19:e1355-e1361. doi: 10.4317/jced.54374. »https://doi.org/10.4317/jced.54374.

Delben JA, Gomes EA, Barão VA, Assunção WG. Evaluation of the effect of retightening and mechanical cycling on preload maintenance of retention screws. Int J Oral Maxillofac Implants. 2011;26:251-6.

Assunção WG, Delben JA, Tabata LF, Barão VA, Gomes EA, Garcia IR Jr. Preload evaluation of different screws in external hexagon joint. Implant Dent. 2012;21:46-50. doi: 10.1097/ID.0b013e31823fcbce. »https://doi.org/10.1097/ID.0b013e31823fcbce.

Conejo J, Kobayashi T, Anadioti E, Blatz MB. Performance of CAD/CAM monolithic ceramic Implant-supported restorations bonded to titanium inserts: a systematic review. Eur J Oral Implantol. 2017;10:139-46.

Alikhasi M, Monzavi A, Bassir SH, Naini RB, Khosronedjad N, Keshavarz S. A comparison of precision of fit, rotational freedom, and torque loss with copy-milled zirconia and prefabricated titanium abutments. Int J Oral Maxillofac Implants. 2013;28:996-1002. doi: 10.11607/jomi.2937. »https://doi.org/10.11607/jomi.2937.

Siadat H, Beyabanaki E, Mousavi N, Alikhasi M. Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections. J Adv Prosthodont. 2017;9:271-7. doi: 10.4047/jap.2017.9.4.271. »https://doi.org/10.4047/jap.2017.9.4.271.

Butignon LE, Basilio MA, Pereira RP, Arioli Filho JN. Influence of three types of abutments on preload values before and after cyclic loading with structural analysis by scanning electron microscopy. Int J Oral Maxillofac Implants. 2013;28:e161-70. doi: 10.11607/jomi.2481. »https://doi.org/10.11607/jomi.2481.

Bickford JH. An Introduction to the designs and behavior of bolted joints. 3rd ed. New York: Marcel Dekker; 1995. p. 213-67.

McLean JW, von Fraunhofer JA. The estimation of cement ?lm thickness by an in vivo technique. Br Dent J. 1971;131:107-11. doi: 10.1038/sj.bdj.4802708. »https://doi.org/10.1038/sj.bdj.4802708.

Lopez-Suarez C, Gonzalo E, Pelaez J, Serrano B, Suarez MJ. Marginal vertical discrepancies of monolithic and veneered zirconia and metal-ceramic threeunit posterior fixed dental prostheses. Int J Prosthodont. 2016;29:256-8. doi: 10.11607/ijp.4541. »https://doi.org/10.11607/ijp.4541.

Pasali B, Sarac D, Kaleli N, Sarac YS. Evaluation of marginal fit of single implant-supported metal-ceramic crowns prepared by using presintered metal blocks. J Prosthet Dent. 2018;119:257-62. doi: 10.1016/j.prosdent.2017.03.015. »https://doi.org/10.1016/j.prosdent.2017.03.015.

Fuda S, Martins BG, Castro FC, Heboyan A, Gehrke SA, Fernandes JC, et al. Marginal Bone level and clinical parameter analysis comparing external hexagon and morse taper implants: a systematic review and meta-analysis. Diagnostics (Basel). 2023;13(9):1587. doi: 10.3390/diagnostics13091587. »https://doi.org/10.3390/diagnostics13091587.

Downloads

Published

2025-01-14

Issue

Section

Original Articles

How to Cite

Limirio, J. P. J. de O., Gomes, J. M. de L., Santiago Junior, J. F., Lemos, C. A. A., Rezende, M. C. R. A., & Pellizzer, E. P. (2025). Influence of manufacturing methods and use of CoCr-based abutments on vertical and horizontal marginal fit and torque loss in implant-supported prostheses. Journal of Applied Oral Science, 33, e20240589. https://doi.org/10.1590/