Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

Authors

  • Maria Regina Guerra MONTEIRO Fluminense Federal University; Department of Orthodontics
  • Licinio Esmeraldo da SILVA Fluminense Federal University; Department of Statistics
  • Carlos Nelson ELIAS Military Engineering Institute; Materials Science Department
  • Oswaldo de Vasconcellos VILELLA Fluminense Federal University; Department of Orthodontics

DOI:

https://doi.org/10.1590/1678-775720130665

Abstract

Objective: To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. Material and Methods: Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric ligatures (TP Orthodontics) were tested. All brackets were tested with archwire 0.019"x0.025" nickel-titanium, beta-titanium, and stainless steel (Unitek/3M). The mechanical testing was performed with a universal testing machine eMIC DL 10000 (eMIC Co, Brazil). The wires were pulled from the bracket slots at a cross-head speed of 3 mm/min until 2 mm displacement. Results: Self-ligating brackets produced significantly lower friction values compared with those of conventional brackets. Frictional force resistance values were directly proportional to the increase in the bracket/ wire angulation. With regard to conventional brackets, stainless steel wires had the lowest friction force values, followed by nickel-titanium and beta-titanium ones. With regard to self-ligating brackets, the nickel-titanium wires had the lowest friction values, significantly lower than those of other materials. Conclusion: even at different angulations, the self-ligating brackets showed significantly lower friction force values than the conventional brackets. Combined with nickel-titanium wires, the self-ligating brackets exhibit much lower friction, possibly due to the contact between nickel-titanium clips and wires of the same material.

Downloads

Download data is not yet available.

Downloads

Published

2014-06-01

Issue

Section

Original Articles

How to Cite

MONTEIRO, M. R. G., SILVA, L. E. da, ELIAS, C. N., & VILELLA, O. de V. (2014). Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations . Journal of Applied Oral Science, 22(3), 228-234. https://doi.org/10.1590/1678-775720130665