PREDICTORES DE FALLO DE EXTUBACIÓN EN LA UNIDAD DE CUIDADOS INTENSIVOS NEONATALES: UNA REVISIÓN SISTEMÁTICA

Autores/as

  • Carine Gomes De Fáveri Federal University of Triângulo Mineiro, Uberaba, (MG), Brazil https://orcid.org/0000-0002-2648-7721
  • Elaine Leonezi Guimarães Federal University of Triângulo Mineiro, Uberaba, (MG), Brazil https://orcid.org/0000-0002-8450-1261
  • Carmem Cervera Morelli Federal University of Triângulo Mineiro, Uberaba, (MG), Brazil
  • Marilita Falangola Accioly Federal University of Triângulo Mineiro, Uberaba, (MG), Brazil https://orcid.org/0000-0002-9623-3145

DOI:

https://doi.org/10.11606/issn.2176-7262.rmrp.2026.220534

Palabras clave:

Bebé, Recién Nacido, Extubación, Factores de riesgo

Resumen

El objetivo de este estudio fue revisar sistemáticamente la literatura científica sobre los predictores de fracaso temprano de la extubación en la Unidad de Cuidados Intensivos Neonatales (UCIN). Se realizó de acuerdo con las recomendaciones del Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), utilizando los siguientes descriptores: extubación, neonato, protocolo, extubación no planificada, cuidados intensivos neonatales, ventilación mecánica, factores de riesgo, lista de verificación. . Inicialmente se encontraron 406 artículos, 55 fueron analizados detalladamente y 6 fueron incluidos en la revisión. Según estudios, los principales motivos del fracaso de la extubación fueron: prematuridad, bajo peso al nacer, enfermedad pulmonar residual, sepsis y anemia. Sin embargo, no se observó evidencia científica sobre el éxito de la extubación temprana en neonatos, recomendándose mayores investigaciones sobre el tema.

Descargas

Los datos de descarga aún no están disponibles.

Biografía del autor/a

  • Carine Gomes De Fáveri, Federal University of Triângulo Mineiro, Uberaba, (MG), Brazil

    Estudiante del Programa de Maestría Académica Asociativa entre la UFTM y la UFU. Universidad Federal del Triángulo Mineiro. Uberaba/MG.

  • Elaine Leonezi Guimarães, Federal University of Triângulo Mineiro, Uberaba, (MG), Brazil

    Profesor Asociado del Departamento de Fisioterapia Aplicada. Profesor-Colaborador del Programa de Maestría Académica Asociativa entre la UFTM y la UFU. Universidad Federal del Triángulo Mineiro. Uberaba/MG.

  • Carmem Cervera Morelli, Federal University of Triângulo Mineiro, Uberaba, (MG), Brazil

    Estudiante del Curso de Fisioterapia. Universidad Federal del Triángulo Mineiro. Uberaba/MG.

  • Marilita Falangola Accioly, Federal University of Triângulo Mineiro, Uberaba, (MG), Brazil

    Profesor Asociado del Departamento de Fisioterapia Aplicada. Profesor del Programa de Maestría Académica Asociativa entre la UFTM y la UFU. Universidad Federal del Triángulo Mineiro. Uberaba/MG

Referencias

1-Al Mandhari H, Finelli M, Chen S, Tomlinson C, Nonoyama ML. Effects of an extubation readiness test protocol at a tertiary care fully outborn neonatal intensive care unit. Canadian journal of respiratory therapy. 2019; 55:81-88.

2-Shalish W, Sant’Anna GM, Natarajan G, Chawla S. When and how to extubate premature infants from mechanical ventilation. Current Pediatrics Reports. 2014;2:18-25.

3-Maheshwari R, Tracy M, Badawi N, Hinder M. Neonatal endotracheal intubation: how to make it more baby friendly. Journal of Paediatrics and Child Health. 2016;52(5):480-486.

4-Al-Mandari H, Shalish W, Dempsey E, Keszler M, Davis P, Sant'Anna G. International survey on peri extubation practices in extremely preterm infants. Archives of Disease in Childhood-Fetal and Neonatal Edition. 2015; 100(5):428-431.

5-Bacci SLIDES, Johnston C, Hattori WT, Pereira JM, Azevedo VMGO . Práticas de desmame da ventilação mecânica nas UTIs pediátricas e neonatais brasileiras: Weaning Survey-Brazil. Jornal Brasileiro de Pneumologia . 2020;(46): 1-10.

6-Teixeira RF et al. Factors associated with extubation failure in very low birth weight infants: a cohort study in northeast Brazil. Journal of Perinatal Medicine. 2021;49(4):506-513.

7-Shalish W et al. Assessment of extubation readiness using spontaneous breathing trials in extremely preterm neonates. JAMA pediatrics. 2020;174(2):178-185.

8-Ouazzani M, Hammady H, Fedorowicz Z, Elmagarmid A. Rayyan—a web and mobile app for systematic reviews. Systematic reviews. 2016;5:1-10.

9-Law M, Stewart D, Letts L, Pollock N, Bosch J, Westmorland M. Guidelines for critical review of qualitative studies. McMaster University occupational therapy evidence-based practice research Group. 1998.

10- Prasad, Rameshwar, Mishra AK. Improvement in successful extubation in newborns after a protocol-driven approach: A quality improvement initiative. Indian pediatrics. 2019;(56): 749-752.

11- Singh N, McNally MJ, Darnall RA. Does diaphragmatic electrical activity in preterm infants predict extubation success? Respiratory Care. 2018;63(2):203-207.

12- Yadav S, Thukral A, Sankar MJ, Sreenivas V, Deorari AK, Paul VK, Agarwal R. Bubble vs conventional continuous positive airway pressure for prevention of extubation failure in preterm very low birth weight infants: a pilot study. The Indian Journal of Pediatrics. 2012;79:1163-1168.

13- Buzzella B, Claure N, D'Ugard C, Bancalari E. A randomized controlled trial of two nasal continuous positive airway pressure levels after extubation in preterm infants. The Journal of pediatrics. 2014; 164(1):46-51.

14- Kahramaner Z, Erdemir A, Turkoglu E, Cosar H, Sutcuoglu S, Ozer EA. Unsynchronized nasal intermittent positive pressure versus nasal continuous positive airway pressure in preterm infants after extubation. The Journal of Maternal-Fetal & Neonatal Medicine. 2014;27(9):926-929.

15- Yoder BA, Stoddard RA, Li M, King J, Dirnberger DR, Abbasi S. Heated, humidified high-flow nasal cannula versus nasal CPAP for respiratory support in neonates. Pediatrics. 2013;131(5): 1482-1490.

16- Kidman AM, Manley BJ, Boland RA, Davis PG, Bhatia R. Predictors and

outcomes of extubation failure in extremely preterm infants. Journal of Paediatrics

and Child Health. 2021;57(6):913-919.

17- Nakato AM, Fm Ribeiro D, Simão AC, Da Silva RP, Nohama P. Impact of

spontaneous breathing trials in cardiorespiratory stability of preterm

infants. Respiratory care. 2021;66(2):286-291.

18- Devadas S, Philip AC. Risk Factors of Extubation Failure in Neonates Admitted to

a Tertiary Care Center. Perinatology. 2018;19(3):91-96.

19- Teixeira C et al. Impacto de um protocolo de desmame de ventilação mecânica

na taxa de falha de extubação em pacientes de difícil desmame. Jornal Brasileiro de

Pneumologia. 2012;38: 364-371.

20- Ferguson KN, Roberts CT, Manley BJ, Davis PG. Interventions to improve rates of successful extubation in preterm infants: a systematic review and meta-analysis. JAMA pediatrics. 2017;171(2):165-174.

Descargas

Publicado

2026-11-18

Número

Sección

Artigo de Revisão

Cómo citar

1.
De Fáveri CG, Guimarães EL, Morelli CC, Accioly MF. PREDICTORES DE FALLO DE EXTUBACIÓN EN LA UNIDAD DE CUIDADOS INTENSIVOS NEONATALES: UNA REVISIÓN SISTEMÁTICA. Medicina (Ribeirão Preto) [Internet]. 18 de noviembre de 2026 [citado 18 de noviembre de 2026];59(1):e-220534. Disponible en: https://revistas.usp.br/rmrp/article/view/220534