Measurement of the flexing force of the fingers by a dynamic splint with a dynamometer

Authors

  • Silmara Nicolau Pedro da Silva University of São Paulo; Faculty of Medicine; Department of Orthopedics
  • Rames Mattar Jr University of São Paulo; Faculty of Medicine; Department of Orthopedics
  • Raul Bolliger Neto University of São Paulo; Faculty of Medicine; Department of Orthopedics
  • Cesar Augusto Martins Pereira University of São Paulo; Faculty of Medicine; Department of Orthopedics

DOI:

https://doi.org/10.1590/S1807-59322005000500006

Keywords:

Hand, Dynamic splint, Dynamometer, Force, Anthropometric measures

Abstract

PURPOSE AND METHODS: In order to determine forces acting upon an articular joint during hand rehabilitation, a dynamic splint was built and connected to a dynamometer (capable of measuring forces in the range 0 - 600 gf). Through trigonometric calculation, the authors measured the flexing force in the proximal interphalangeal joint of the middle finger at 30°, 45°, 60°, and 90° of flexion. Measurements were obtained in a population of 40 voluntary adults, 20 females and 20 males, This flexing force was correlated with age, sex, and anthropometric measures. RESULTS: Force in the flexing tendon is maximal at the start of flexion, and decreases as the angle of joint flexion increases. A relationship was observed between finger length and the magnitude of the force exerted on the tendon: the longer the finger, the greater the force exherted upon the tendon. Force is greater at all the measured angles, (except 30°) in males and in individuals of higher stature, and bigger arm span. CONCLUSIONS: The flexing force can be effectively measured at all flexing angles, that it correlates with a number of different anthropometric parameters, and that such data are likely to open the way for future studies.

Downloads

Download data is not yet available.

Downloads

Published

2005-10-01

Issue

Section

Original Research

How to Cite

Silva, S. N. P. da, Mattar Jr, R., Bolliger Neto, R., & Pereira, C. A. M. (2005). Measurement of the flexing force of the fingers by a dynamic splint with a dynamometer . Clinics, 60(5), 381-388. https://doi.org/10.1590/S1807-59322005000500006