Validation of spectrophotometric methodology for quantify flavonoid content in Bauhinia cheilantha (Bongard) Steudel

Authors

  • Tadeu José da Silva Peixoto Sobrinho Universidade Federal de Pernambuco; Centro de Ciências da Saúde; Departamento de Ciências Farmacêuticas; Laboratório de Produtos Naturais
  • Carlos Henrique Tabosa Pereira da Silva Universidade Federal de Pernambuco; Centro de Ciências da Saúde; Departamento de Ciências Farmacêuticas; Laboratório de Produtos Naturais
  • João Eudes do Nascimento Universidade Federal de Pernambuco; Centro de Ciências da Saúde; Departamento de Ciências Farmacêuticas; Laboratório de Produtos Naturais
  • Júlio Marcelino Monteiro Universidade Federal Rural de Pernambuco; Departamento de Biologia; Laboratório de Etnobotânica
  • Ulysses Paulino de Albuquerque Universidade Federal Rural de Pernambuco; Departamento de Biologia; Laboratório de Etnobotânica
  • Elba Lúcia Cavalcanti de Amorim Universidade Federal de Pernambuco; Centro de Ciências da Saúde; Departamento de Ciências Farmacêuticas; Laboratório de Produtos Naturais

DOI:

https://doi.org/10.1590/S1516-93322008000400015

Keywords:

Spectrophotometry^i2^smethod's validat, Rutin^i2^s, Bauhinia cheilautha^i2^spharmacogno, Flavonoids^i2^squantificat, Phytotherapics^i2^squality cont

Abstract

Phytotherapeutic laboratories require access to methodologies that guarantee quality control for their products when these items are not already registered in pharmacopeias or official monographs. As such, the present study sought to validate analytical methodologies for quantifying natural flavonoids contained in extracts of "pata-de-vaca" (Bauhinia cheilantha [Bong.] Steudel) using visible light spectrophotometry and a rutin standard (µg/ml). All of the parameters required by ANVISA were evaluated. The specificity test revealed a maximum absorption peak at 420 nm. The methodology was considered linear and of high quantification sensitivity (2.51 µg/ml). The methodology also proved to be robust, and had high recovery levels (98.36%). The results obtained for repeatability, intermediate precision (intra- and inter-day), and reproducibility all certified the precision of the method, with values between 0.31 and 3.58%; the methodology was also considered exact (95.71-105.50%). This study demonstrated that the proposed methodology can be considered specific, precise, reproducible, exact, of low cost, and easy to perform.

Downloads

Download data is not yet available.

Published

2008-12-01

Issue

Section

Original Papers

How to Cite

Validation of spectrophotometric methodology for quantify flavonoid content in Bauhinia cheilantha (Bongard) Steudel. (2008). Revista Brasileira De Ciências Farmacêuticas, 44(4), 683-689. https://doi.org/10.1590/S1516-93322008000400015