Development and testing of a text messaging (SMS) monitoring software application for acute decompensated heart failure patients
DOI:
https://doi.org/10.1590/1518-8345.3519.3301Keywords:
Telemedicine, Heart Failure, Medical Informatics, Monitoring, Text Messaging, Nursing EducationAbstract
Objective: to develop and test an SMS monitoring software application for patients with acute decompensated heart failure. Method: the waterfall model was used for software development. All expected functionalities were defined, program modules were codified and tests were done so as to ensure good performance by the software application. Ten patients participated in the prototype test. Results: the system sends two types of messages: questions that should be answered by patients and unilateral educational reinforcements. In addition, the system generates alarms in case of no response or according to a flow chart to detect congestion in the patient previously created by the team. Of the 264 SMS texts sent, 247 were answered. The alarm was triggered seven times: three patients woke up with shortness of breath for two consecutive nights, and four patients felt more fatigued for two consecutive days. All patients took the prescribed medications during follow-up. The study nurse guided the patients who generated alarms in the system. Conclusion: the SMS software application was successfully developed and a high response rate and preliminary evidence of improvements in self-management of HF were observed. With this regard, telehealth is a promising alternative in the treatment of chronic diseases
Downloads
Downloads
Published
Issue
Section
License
Copyright (c) 2020 Revista Latino-Americana de Enfermagem

This work is licensed under a Creative Commons Attribution 4.0 International License.
RLAE’s authorship concept is based on the substantial contribution by each of the individuals listed as authors, mainly in terms of conceiving and planning the research project, collecting or analyzing and interpreting data, writing and critical review. Indication of authors’ names under the article title is limited to six. If more, authors are listed on the online submission form under Acknowledgements. The possibility of including more than six authors will only be examined on multicenter studies, considering the explanations presented by the authors.Including names of authors whose contribution does not fit into the above criteria cannot be justified. Those names can be included in the Acknowledgements section.
Authors are fully responsible for the concepts disseminated in their manuscripts, which do not necessarily reflect the editors’ and editorial board’s opinion.