Pico de flujo de tos en niños en edad preescolar: tasa de éxito y reproducibilidad test-retest

Autores/as

  • Danielle Corrêa França Universidade Federal de Minas Gerais; Programa de Pós-Graduação em Ciências da Reabilitação
  • Paulo Augusto Moreira Camargos Universidade Federal de Minas Gerais (UFMG) – Belo Horizonte (MG), Brasil
  • Bruna da Silva Pinto Pinheiro Vieira Hospital Municipal Odilon Behrens. MG. Brasil
  • Danielle Aparecida Gomes Pereira Universidade Federal de Minas Gerais (UFMG) – Belo Horizonte (MG), Brasil
  • Verônica Franco Parreira Universidade Federal de Minas Gerais (UFMG) – Belo Horizonte (MG), Brasil

DOI:

https://doi.org/10.590/1809-2950/13838722032015

Resumen

La evaluación de la función pulmonar en niños en edad preescolar es importante pues hay pocos estudios que investigan los test de función pulmonar en este grupo. Este estudio tuvo el propósito de evaluar la tasa de éxito y la reproducibilidad test-retest del pico de flujo de tos (PFT) en una muestra con niños entre 4 y 6 años de edad. Se estudió el PFT en 44 participantes saludables (26 chicos y 18 chicas) elegidos a través de un cuestionario ATS-DLD-78-C para detectar la presencia de enfermedades respiratorias de base y exposición ambiental. Se utilizó el medidor del pico de flujo espiratorio (Piko-I Electronic Peak Flow Meter, Pulmonary Data Services, USA) para medir el PFT. Se definió la tasa de éxito como el porcentaje de niños capaces de realizar el test según los criterios de aceptabilidad y de reproducibilidad. Para evaluar la reproducibilidad test-retest tras tres semanas se reevaluaron 10 niños según el cálculo de la muestra. Se analizó la reproducibilidad a través del test t pareado, considerando significativo <0,05 y el coeficiente de correlación intraclase (CCI). Los resultados mostraron una tasa de éxito del 91% para el PFT, siendo un 80, 88 y 100% para niños con 4, 5 y 6 años, respectivamente. En cuanto a la reproducibilidad test-retest no hubo diferencias significativas entre los datos de la primera evaluación y de la reevaluación (p=0,39) en que se observó el CCC de 0,84. Estos resultados proponen alta tasa de éxito en la ejecución del PFT y excelente reproducibilidad test-retest en esa variable en niños saludables en edad preescolar.

Descargas

Los datos de descarga aún no están disponibles.

Referencias

Salam A, Tilluckdharry L, Amoateng-Adjepong Y, Manthous

CA. Neurologic status, cough, secretions and extubation

outcomes. Intensive Care Med. 2004;30(7):1334-9.

Freitas FS, Parreira VF, Ibiapina CC. Aplicação clínica do pico

de fluxo da tosse: uma revisão de literature. Fisioter Mov.

;23(3):495-502.

Bach JR, Saporito LR. Criteria for extubation and tracheostomy

tube removal for patients with ventilatory failure. A different

approach to weaning. Chest. 1996;110(6):1566-71.

Chan LY, Jones AY, Chung RC, Hung KN. Peak flow rate during

induced cough: a predictor of successful decannulation of a

tracheotomy tube in neurosurgical patients. Am J Crit Care.

;19(3):278-84.

Bianchi C, Baiardi P. Cough peak flows: standard values

for children and adolescents. Am J Phys Med Rehabil.

;87(6):461-7.

Paschoal IA, Villalba WO, Pereira MC. Chronic respiratory

failure in patients with neuromuscular diseases: diagnosis

and treatment. J Bras Pneumol. 2007;33(1):81-92.

Bach JR. Mechanical insufflation-exsufflation. Comparison of

peak expiratory flows with manually assisted and unassisted

coughing techniques. Chest. 1993;104(5):1553-62.

Brito MF, Moreira GA, Pradella-Hallinan M, Tufik S. Air

stacking and chest compression increase peak cough flow in

patients with Duchenne muscular dystrophy. J Bras Pneumol.

;35(10):973-9.

Chatwin M, Simonds AK. The addition of mechanical

insufflation/exsufflation shortens airway-clearance sessions

in neuromuscular patients with chest. infection. Respir Care.

;54(11):1473-9.

Fauroux B, Guillemot N, Aubertin G, Nathan N, Labit

A, Clement A, et al. Physiologic benefits of mechanical

insufflation-exsufflation in children with neuromuscular

diseases. Chest. 2008;133(1):161-8.

Gauld LM. Airway clearance in neuromuscular weakness. Dev

Med Child Neurol. 2009;51(5):350-5.

Ishikawa Y, Bach JR, Komaroff E, Miura T, Jackson-Parekh R.

Cough augmentation in Duchenne muscular dystrophy. Am

J Phys Med Rehabil. 2008 ;87(9):726-30.

Kang SW, Kang YS, Sohn HS, Park JH, Moon JH. Respiratory

muscle strength and cough capacity in patients with

Duchenne muscular dystrophy. Yonsei Med J. 2006;

(2):184-90.

Miske LJ, Hickey EM, Kolb SM, Weiner DJ, Panitch HB.

Use of the mechanical in-exsufflator in pediatric patients

with neuromuscular disease and impaired cough. Chest.

;125(4):1406-12.

Sancho J, Servera E, Diaz J, Marin J. Efficacy of mechanical

insufflation-exsufflation in medically stable patients with

amyotrophic lateral sclerosis. Chest. 2004;125(4):1400-5.

Dohna-Schwake C, Ragette R, Teschler H, Voit T, Mellies U.

IPPB-assisted coughing in neuromuscular disorders. Pediatr

Pulmonol. 2006;41(6):551-7.

Beydon N, Davis SD, Lombardi E, Allen JL, Arets HG, Aurora

P, et al. An official American Thoracic Society/European

Respiratory Society statement: pulmonary function

testing in preschool children. Am J Respir Crit Care Med.

;175(12):1304-45.

Eigen H, Bieler H, Grant D, Christoph K, Terrill D, Heilman DK,

et al. Spirometric pulmonary function in healthy preschool

children. Am J Respir Crit Care Med. 2001;163(3 Pt 1):619-23.

Burity EF, Pereira CA, Rizzo JA, Sarinho ES, Jones MH.

Early termination of exhalation: effect on spirometric

parameters in healthy preschool children. J Bras Pneumol.

;37(4):464-70.

Esteves A. Adaptação e validação do quetionário ATS-DLD78-C para diagnóstico de asma em crianças com até 13 anos

[dissertação]. Universidade Federal de São Paulo; 1995.

Borrego LM, Pinto PL, Neuparth N, Pinto JR. Função

respiratória na criança em idade pré-escolar. Revista

Portuguesa de Imunoalergologia. 2004;12(3):365-72.

Drumond S. Valores de referência de parâmetros

espirométricos em crianças e adolescentes com diferentes

índices de massa corporal [dissertação]. Universidade

Federal de Minas Gerais; 2006.

Portney LG, Watkins MP. Foundations of clinical research:

applications to practice. 3rd ed. New Jersey:Prentice Hall;

Sancho J, Servera E, Diaz J, Marin J. Predictors of ineffective

cough during a chest infection in patients with stable

amyotrophic lateral sclerosis. Am J Respir Crit Care Med.

;175(12):1266-71.

Rodrigues JC, Cardieri JM, Bussamra MH, Nakaie CM, Almeida

MB, Filho LV, et al. Provas de função pulmonar em crianças e

adolescentes. J Bras Pneumol 2002;28(3):207-21.

Aurora P, Stocks J, Oliver C, Saunders C, Castle R,

Chaziparasidis G, et al. Quality control for spirometry in

preschool children with and without lung disease. Am J

Respir Crit Care Med. 2004;169(10):1152-9.

Gaffin JM, Shotola NL, Martin TR, Phipatanakul W. Clinically

useful spirometry in preschool-aged children: evaluation of

the 2007 American Thoracic Society Guidelines. J Asthma.

;47(7):762-7.

Marostica PJ, Weist AD, Eigen H, Angelicchio C, Christoph K,

Savage J, et al. Spirometry in 3- to 6-year-old children with

cystic fibrosis. Am J Respir Crit Care Med. 2002;166(1):67-71.

Nystad W, Samuelsen SO, Nafstad P, Edvardsen E, Stensrud

T, Jaakkola JJ. Feasibility of measuring lung function in

preschool children. Thorax. 2002;57(12):1021-7.

Mayer OH, Clayton RG, Sr., Jawad AF, McDonough JM, Allen

JL. Respiratory inductance plethysmography in healthy 3- to

-year-old children. Chest. 2003;124(5):1812-9.

Publicado

2015-09-09

Número

Sección

Artigos

Cómo citar

Pico de flujo de tos en niños en edad preescolar: tasa de éxito y reproducibilidad test-retest . (2015). Fisioterapia E Pesquisa, 22(3), 275-281. https://doi.org/10.590/1809-2950/13838722032015